0.5.8

Support for SHT31 SHT31:

  • Accuracy: ±2% RH and ±0.3°C - better than most I2C sensors
  • Response time: <8 seconds for humidity
  • Operating range: up to 125°C and 0-100% RH
  • Resistant to condensation - crucial when drying down to 0%
  • Calibrated and stable - no manual calibration required Unlike DHT22, AM2302, and similar sensors, it performs reliably at high temperatures and doesn’t fail due to overheating.

0.5.7

Refactoring, improved operational stability

0.5.6

  • 110°C option added in config
  • Updated temperature control algorithm

0.5.5

(no changelog provided)

0.5.4

(no changelog provided)

0.5.3

  • Added audio alerts for temperature sensor issues at startup:

  • Short beeps: BME startup issue (long cable or poor contact)

  • Long beeps: out-of-range thermistor values (wrong thermistor type, incorrect divider resistor, bad contact, or extreme temperature)
  • Changed error accumulation logic for temperature and humidity readings
  • Adjusted polling rate and data filtering for BME280
  • Minor bug fixes

0.5.2

0.5.1

  • Scale support added
  • Frequency selection for scale polling: 10/80Hz
  • Improved weight reading stability
  • English language support added
  • Non-blocking servo now runs on a timer
  • Minor improvements and enhanced firmware stability

0.5.0

  • Scale config implemented
  • Median filter for scale data
  • Auto-PID only runs when AUTOPID_RUN != 1 if scales are in use
  • Preset names moved to config
  • Zero calibration added
  • Tare weight can be set in the menu
  • Replaced float with integer for mass; scales now round down to nearest whole number (e.g., 999.99 = 999)
  • Bootloader removed as it’s no longer necessary

0.4.4

  • Increment/decrement by 10 when rotating encoder quickly
  • Improved input interface responsiveness
  • Encoder and button use interrupts

0.4.3

  • Servo test works without saving
  • PWM frequency test added based on "Fan" variable
  • Fixed servo functionality
  • Preset modes functioning properly

0.4.2

  • Servo test added

0.4.1

  • Servo2 not supported
  • min/max temp checks (tmpTemp <= ADC_MIN || tmpTemp >= ADC_MAX) only active during drying and storage

0.4.0

  • Buzzer must be active type
  • PWM frequency selection for pin 11 configurable in configuration.h (for noisy fans)
  • HX711 library tested and integrated

Version 0.3.6

  • Refactored servo handling block

Version 0.3.5

  • First stable version for public use
git commit --allow-empty -m "0.3.6 final"